Genset
Monitoring
Total visibility into your diesel generator — electrical parameters, engine health, oil & coolant levels, and RPM — with instant alerts at every fault level.
- check_circleAll electrical parameters in real time
- check_circleOil, coolant & fuel level monitoring
- check_circlePre-alarm → Warning → Critical shutdown alerts
- check_circleCPCB & IS/IEC compliance reporting
Parameters
Everything Your Genset Tells You
Every sensor value streamed live to your dashboard and stored for trend analysis.
Section 1
Electrical Parameters
Voltage (L-L / L-N)
3-Phase, ±0.5% accuracy
Current (Per Phase)
Up to 6000A via CT
Active Power (kW)
Import / Export tracking
Reactive Power (kVAR)
Lead / Lag detection
Power Factor
Per-phase & aggregate
Frequency (Hz)
49–51 Hz ±0.1 Hz
kWh / kVAh
Import / Export registers
THD — Harmonics
Up to 31st harmonic
Section 2
Engine & Fluid Parameters
Engine RPM
Optical / magnetic pickup
Coolant Temperature
PT100 or 4–20 mA sensor
Engine Oil Pressure
0–10 bar, 4–20 mA
Fuel Level
Ultrasonic / float sensor
Oil Level
Low / OK / High status
Air Filter Differential
Differential pressure
Battery Voltage
12 V / 24 V DC
Run Hours
Tamper-proof meter
Alert System
Three-Level Alert System
Know exactly how serious a fault is — and take the right action — before it escalates.
- warningFuel level < 30%
- warningCoolant temp > 85 °C
- warningOil pressure < 3.5 bar
- warningBattery voltage < 12.2 V
- warningEngine RPM ±5% of setpoint
- warningFuel level < 15%
- warningCoolant temp > 95 °C
- warningOil pressure < 2.5 bar
- warningHigh coolant temperature
- warningOver / Under voltage (±10%)
- warningFuel level < 5% (dry-run protection)
- warningCoolant temp > 105 °C (overheat)
- warningOil pressure < 1.5 bar (low lube)
- warningEngine RPM > 110% (overspeed)
- warningPhase loss / reverse phase
opacityOil & Coolant Level Detail
Each fluid is monitored with dedicated sensors and reported as a percentage or discrete level (Low / OK / High). Alerts fire independently at every threshold so you never miss a degrading trend.
Simulated live values — updates every 500 ms
Technical Details
Technical Specifications
Comprehensive details for system integrators and IT managers.
memoryHardware — Gateway
expand_more
Hardware — Gateway
- Modbus RTU / TCP, RS-485, CAN bus, 4–20 mA, dry contacts
- Onboard storage: 32 GB (≈ 2 years at 1-second intervals)
- Operating range: –20 °C to +70 °C, IP65 enclosure
- Power: 9–36 V DC; built-in UPS for 4-hour ride-through
sensorsSupported Sensors
expand_more
Supported Sensors
- Voltage: direct 110–690 V or via VT (up to 33 kV)
- Current: split-core CT (50–6000 A), Rogowski coil
- Temperature: PT100, PT1000, NTC, J/K thermocouple
- Level: ultrasonic, float switch, capacitive probe
apiConnectivity & Protocols
expand_more
Connectivity & Protocols
REST API and MQTT broker included. Integrates with SCADA (OPC-UA), ERP, and maintenance platforms like Limble CMMS. Cellular 4G LTE and Wi-Fi backup links ensure zero data loss even during LAN outages.
bar_chartReporting & Compliance
expand_more
Reporting & Compliance
Automated PDF/Excel reports: fuel consumption per run, load profile, fault history, and maintenance due reminders. Audit-ready logs with tamper-evident timestamps satisfy IS/IEC 60034 and CPCB generator compliance requirements.
Stop discovering faults after the shutdown.
Get a live demo of the WhereFy Genset Monitor on your actual generator — no obligation, no generic slides.